Hypertherm Waterjet Intensifier Pumps

Easy to Operate. Easy to Maintain.

/

Hypertherm HyPrecision Intensifier Pumps

WARDJet offers a full range of reliable, efficient waterjet intensifier pumps from Hypertherm. These waterjet pumps are designed for around-the-clock operations, small prototype jobs, and every application in between. All Hypertherm pumps are engineered to be easy to operate - and even easier to maintain. WARDJet is Hypertherm's #1 waterjet partner and offers a full line of service, support and parts for all makes and models of waterjet pumps. WARDJet's team of expert field technicians can also service your existing equipment, even if it isn't a Hypertherm pump.
Toggle Imperial or Metric
Model Max Ouput Flow Max Orifice Max Pressure Configuration Power Bleed-Down Valve Motor Starter
Echion 15 0.30 gpm 0.007" 60,000 psi Single 15hp Air ATL
Echion 30 0.60 gpm 0.011" 60,000 psi Single 30hp Air ATL/Wye-Delta/Soft Start
Echion 50 1.0 gpm 0.014" 60,000 psi Single 50hp Air Wye-Delta/Soft Start
P-Series 50S 1.0 gpm 0.014" 60,000 psi Single or Redundant 50hp Air True Soft Start
P-Series 60S 1.2 gpm 0.016" 60,000 psi Single 60hp Air True Soft Start
P-Series 75S 1.5 gpm 0.017" 60,000 psi Single or Redundant 75hp Air True Soft Start
D-Series 100D 2.2 gpm 0.021" 60,000 psi Dual 100hp Hydraulic True Soft Start
D-Series 150D 3.2 gpm 0.025" 60,000 psi Dual 150hp Hydraulic True Soft Start

Hypertherm Pump Comparison

Scroll to see entire chart

  hp30 hp30 hp30 hp30
  Echion Series Predictive Series D-Series
  Echion 15 Echion 30 Echion 50 P-Series 50S P-Series 60S P-Series 75S D-Series 100D D-Series 150D
  50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Maximum output flow 0.30 gpm
(1.1 lpm)
0.60 gpm
(2.3 lpm)
1.0 gpm
(3.8 lpm)
1.0 gpm
(3.79 lpm)
1.1 gpm
(4.16 lpm)
1.2 gpm
(4.54 lpm)
1.3 gpm
(4.92 lpm)
1.5 gpm
(5.68 lpm)
1.6 gpm
(6.06 lpm)
2.1 gpm
(7.95 lpm)
2.2 gpm
(8.33 lpm)
3.0 gpm
(11.36 lpm)
3.2 gpm
(12.11 lpm)
Maximum orifice 0.007"
(0.18 mm)
0.011"
(0.28 mm)
0.014"
(0.35 mm)
0.014"
(0.356 mm)
0.015"
(0.38 mm)
0.016" (0.406 mm) 0.017"
(0.432 mm)
0.018"
(0.457 mm)
0.020"
(0.508 mm)
0.021"
(0.533 mm)
0.024"
(0.610 mm)
0.025"
(0.635 mm)
Continuous output pressure Adjustable to 60,000 psi (4137 bar)
Intensifier configuration Single Single or Redundant Single Single or Redundant Dual
Pressure control Closed Loop Proportional Electronic Proportional
Bleed-down valve Air Hydraulic
 
Motor Power 15hp
(11.2 kW)
30hp
(22.4 kW)
50hp
(37.3 kW)
50hp
(37.3 kW)
60hp
(44.7 kW)
75hp
(56 kW)
100hp
(74.6 kW)
150hp
(111.9 kW)
Voltage 400 V 208-230/460 V 400 V 208-230/460 V 400 V 208-230/460 V 400 V 208-230/460 V 400 V 460 V 400 V 460 V 400 V 460 V 400 V 460 V
Full load 23 A 45-41/21 A 44 A 83-75/38 A 73 A 135-122/61 A 73 A 138-125/62 A 75 A 71.1 A 103 A 87.1 A 138 A 117.5 A 204 A 173.4 A
Main breaker 30 A 60 / 30 A 50 A 200 / 50 A 100 A 175 / 100 A 80 A 150 / 80 A 100 A 125 A 100 A 150 A 225 A
Motor starter ATL Wye Delta/Soft Start ATL / ATL/Soft Start Wye-Delta/Soft Start Soft Start True Soft Start
Overall width 43" (1090 mm) 40" (1016 mm) 45" (1143 mm) 55" (1397 mm)
Overall length 53" (1350 mm) 79" (1996 mm) 86" (2184 mm) 81" (2057 mm)
Overall height 40" (1010 mm) 59" (1509 mm) 56" (1422 mm) 56" (1422 mm)
Approximate operating weight 1700 lb (775 kg) 1850 lb (825 kg) 2050 lb (925 kg) 2800 lb (1300 kg) 3200 lb (1450 kg) 3300 lb (1500 kg) 4150 lb (1882 kg) 6100 lb (2767 kg)
Additional Items
  Optional internal air-over-oil cooler Optional external air-over-oil cooler Optional external air-over-oil cooler
  Optional internal boost pump Standard internal boost pump Standard internal boost pump
  Optional metric conversion kit Cover with viewing window Optional water isolation valves Standard water isolation valves
  - Optional electrical interlock -
Hydraulic Cooling Water (if not air cooled)
  Echion 15 Echion 30 Echion 50 HyPrecision P-Series 50S HyPrecision P-Series 60S HyPrecision P-Series 75S HyPrecision 100D HyPrecision 150D
  50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Normal Inlet Flow Rate 3 gpm (11.5 lpm) 8 gpm (30 lpm) 10 gpm (38 lpm)
Min. Inlet Water Pressure 40 psi (2.76 bar)
Max. Inlet Water Pressure 115 psi (7.93 bar)
Max. Inlet Temp. 70°F (21°C)
Min. Inlet Temp 40°F (4.4°C)

Supported Orifice Combinations

Orifice combinations supported by the HyPrecision pumps

Echion 15

Orifice size in (mm)
1 orifice 0.007 (0.18)
2 orifices 0.005 (0.13)
3 orifices 0.004 (0.10)
4 orifices -
5 orifices -
6 orifices -

Echion 30

Orifice size in (mm)
1 orifice 0.011 (0.28)
2 orifices 0.007 (0.18)
3 orifices 0.006 (0.15)
4 orifices 0.005 (0.13)
5 orifices 0.004 (0.10)
6 orifices -

Echion 50

Orifice size in (mm)
1 orifice 0.014 (0.35)
2 orifices 0.010 (0.25)
3 orifices 0.008 (0.20)
4 orifices 0.007 (0.18)
5 orifices 0.006 (0.15)
6 orifices 0.005 (0.13)

Nozzle and Orifice Combinations

Orifice Nozzle Abrasive (lb/min) Abrasive mesh
0.007 0.020 0.25 120 - 220
0.009 0.030 0.4 - .6 80 - 120
0.010 0.030 0.5 - .75 80 - 120
0.013 0.040 1.0 - 1.25 60 - 80
0.014 0.040 1.1 - 1.35 60 - 80
0.015 0.040 1.25 - 1.5 60 - 80
0.016 0.040 1.3 - 1.5 60 - 80

Typical combinations by pump size

HP Qty heads Orifice/Nozzle
30 1 .010/.030
30 2 .006 water
50 1 .014/.040
50 2 .010/.030

Power vs. flow for HyPrecision waterjet pumps

Model Power Pressure Max. output flow Max. orifice size
  hp kW psi bar GPM L/min in mm
15 15 11.2 60,000 4137 0.3 1.1 0.007 0.18
30 30 22 60,000 4137 0.60 2.30 0.011 0.28
50 50 37 60,000 4137 1.00 3.80 0.014 0.35

Start Cutting!